7.15.1 Warnings
Warning events let you know that something related to the Galaxy 65 Subsystem or an array has a 
problem. You should correct the problem as soon as possible. 
Table 7–4
 defines each warning event and 
recommends the action you should take.
Table 7–4
Warning events
Event
Definition
Recommended Action
ARRAY CRITICAL One or more drives are down and the 
array is online, but is no longer fault 
tolerant.
Add a spare to the array or the spare 
pool. Then replace the bad drives. 
Refer to the Galaxy 65 Subsystem 
Getting Started Guide
.
ARRAY OFFLINE
More than one drive in a RAID 0 or 
volume set went down bringing the 
array to an offline state. This array is 
no longer accessible by the host.
Replace the bad drive and restore the 
data from backup.
BATT FAIL INFO
A warning condition in the battery pack 
or charging interface has been 
detected.
Replace the battery, see section 
7.12.5 on page 74
.
BOOT ONLINE 
FAIL
During startup, the system attempted 
to put the specified module online. 
This operation failed. 
The event gives a reason why the Put 
Online failed. Examine this reason and 
take the appropriate action. If the 
reason is DIAGNOSTIC FAIL, a 
hardware problem was found with the 
module. In this case, try replacing the 
module with a different one.
DISK CHAN 
DEGRAD
Errors detected on one of the disk 
channels have caused the Galaxy 65 
Subsystem to mark the channel as 
degraded. 
Determine the source of the errors on 
the specified disk channel and replace 
the faulty hardware.
DRIVE DOWN
An error occurred with the drive and it 
was downed, removing it from the 
active array.
Add a spare to the array or the spare 
pool. Then replace the bad drive. Refer 
to the Galaxy 65 Subsystem Getting 
Started Guide
.
HW STATUS 
CHANGE
A SM has detected a significant 
change in the status of one of the 
power modules. 
If the event indicates that the module 
has failed or is not present, install a 
new module.