6. V-Link
3-27
Ser
Data Items for Protocols
• Transmission control code: 1 byte
• V7 port number: 2 bytes
Port numbers are used so that the host computer can identify each V7 series for 
access.  The data range is from 01H to 1FH (1 to 31) and is converted into the ASCII 
code before use.  The port number of the V7 series should be set on the V-SFT editor.  
(Refer to “V-SFT Setting.”)
• Command: 2 bytes
Available commands are shown below.
• The number of words to be read or written: 2 bytes
Set the number of words to be read or written by one command.  The data range is from 
01H to FFH (1 to 255) and is converted into the ASCII code before use.
• Memory address to be read or written: 18 bytes
Specify the memory address to be accessed.  Set the following code in the format as 
shown for “Read target memory setting” on page 3-25 and “Write target memory 
setting” on page 3-26.
- Model
Signal Name
Code (Hexadecimal)
Contents
STX
02H
Start of transmission block
ETX
03H
End of transmission block
CR
0DH
Carriage return
LF
0AH
Line feed
Name
Code (Hexadecimal)
ASCII
Contents
Read
20H
32 30
Read from memory
Write
21H
32 31
Write to memory
Code (Hexadecimal)
ASCII
V7 series internal memory
00H
3030
PLC memory
16-bit
01H
3031
32-bit
81H
3831
Memory card
02H
3032
Temperature control/PLC2 memory
16-bit
03H
3033
32-bit
83H
3833