7. Mounting Procedure
7.
Mounting Procedure
Mounting Procedure
1. Cut out the mounting panel (max. thick: 5 mm) to match the dimensions shown below.
2. Insert four fixtures attached to the V7 series into the mounting holes, and tighten them 
with the locking screws.
Tightening torque
V708/V708i/V710/V710i: 0.3 to 0.5 N•m
V712/V712i:
0.5 to 0.7 N•m
* When the V7 unit is attached to the 
mounting panel, the fixtures and frame 
grounds (FG) are connected.  To prevent 
static electricity, be sure to connect the 
mounting panel to the frame ground.
3. Mount the gasket in contact with the mounting panel so that it will be sandwiched 
securely between the unit and the mounting plate.
Mounting Angle
Install the unit within the angle of 15
° to 135° degrees as 
shown on the right.
165.5
220.5
+
0.5
0
0
+
0.5
246.2
313
V712/V712i
V708/V708i
216.2
289
+
0.5
0
0
+
0.5
V710/V710i
+
0.5
0
0
+
0.5
F1
F2
F3
F4
F5
F6
F7
SYS
TEM
POW
ER
216.2
289
+0.5
0
0
+
0.5
Mounting panel
Panel cut-out hole
• Panel cut-out dimensions
(Unit: mm)
MJ1
MJ2
PRIN
TER
CF
CN5
MEM
ORY
CN6
LAN
CN1
100-
240V
AC
L     
  N
Fixtures
Mounting hole
Mounting hole
V7 series
Mounting panel
Fixtures
17.8
10.5
30.0
Fixture dimensions
(Unit: mm)
15
°
135
°
90
°
0
°
Disp
lay
D
is
pl
ay