Enviro EG 33 Manual De Usuario

Descargar
Página de 22
TROUBLE SHOOTING 
 
Problem 
Possible Cause 
Solution 
Spark will not light the pilot after 
repeated pressing of spark igniter 
Defective piezo igniter 
Check connections to igniter 
-If igniter connections are good but 
there is no spark-replace igniter 
 
Broken spark electrode 
-Check for broken ceramic insulation 
replace, electrode if broken 
 
Miss-aligned spark electrode 
-If spark is not arcing from the 
electrode to pilot- adjust by loosening 
screws on pilot base.  Adjust and re-
tighten 
Pilot will not remain lit 
Problem with thermocouple circuit 
-Check for proper connection of 
thermocouple to rear of valve.  If 
loose, tighten lightly 
-Check pilot for full flame 
impingement around thermocouple.  
If the pilot is to small - Check gas 
pressure, adjust pilot rate screw, 
check pilot head for blockage. 
-Check thermocouple voltage at 
valve- must be greater than 5 mV.  If 
low, replace thermocouple. 
 
Air in gas line - (Pilot flame dies while knob 
is depressed.) 
-Bleed line. 
-Check gas line pressure. 
-Contact dealer. 
Burners will not remain lit 
Problem with thermopile circuit  
-Check gas line pressure. 
-Check for flame impingement on 
thermopile, if low see “Pilot will not 
stay lit” 
-Check thermopile for a Minimum of 
220 mV        when burner switched 
on. 
-Check wiring to thermostat for 
breaks. 
Flame lifting 
Leak in vent pipe 
Improper vent configuration 
Terminal may be recirculating flue gases 
-Check for leaks in vent connections  
-Check vent configuration with 
manual  
-Check to see if terminal is on 
correctly 
-May need to install high wind 
termination cap 
-Contact dealer. 
Glass fogs up 
Normal conditions - after the appliance warms up glass will clear 
** Due to additives in gas, glass may get hazy during normal use** 
    Clean when needed. 
Blue flames 
 
Normal during start - flame will yellow as the 
appliance heats up. 
 
Flames are burning “dirty” or 
Sooting 
Flame impingement 
-Check log position 
-Increase primary air by opening 
venturi shutters 
See also “Burners will not stay lit” 
 
 
 
 
 
 
 
 
17