Emerson Avocent HMX Digital High Performance KVM Switch Guía De Instalación
32 HMX Extender System Installer/User Guide
To close the OSD:
Press ESC or use the mouse to click the X button on the top right-hand corner of the OSD.
The Serial Menu
The HMX user station incorporates a serial menu that allows you to:
•
Configure network settings for the HMX user station
•
Configure network settings for the transmitter
•
Set or change passwords
•
Upgrade firmware for the HMX user station and transmitter
•
Reset to factory defaults
•
Set a session time-out value
•
Change the audio performance settings
•
Configure the transmitter for normal aspect or wide screen resolutions
Accessing the serial menu
You can access the serial menu via the serial port on the back of the HMX user station. All terminal
commands are executed through a terminal or computer running HyperTerminal
commands are executed through a terminal or computer running HyperTerminal
®
emulation software
or equivalent. By default, two passwords are required to access the HMX user station via the
transmitter. One password controls access to the user station, the other password controls access to
the transmitter. In both cases, the default password is password.
transmitter. One password controls access to the user station, the other password controls access to
the transmitter. In both cases, the default password is password.
Items needed to access the serial menu
•
Networked workstation with a serial port
•
Null-modem serial cable (male DB9) or three-wire serial cable
•
HyperTerminal emulation software or equivalent
NOTE: When utilizing the serial menu screens, the HMX user station is sometimes referred to as the receiver.
To access the serial menu:
1. Connect one end of the serial cable to the serial port on the back of the HMX user station.
2. Connect the other end of the serial cable to the serial port of your computer.
3. Launch HyperTerminal.
4. Within the COM1 Properties Port Settings tab, configure the HyperTerminal session for 57600
2. Connect the other end of the serial cable to the serial port of your computer.
3. Launch HyperTerminal.
4. Within the COM1 Properties Port Settings tab, configure the HyperTerminal session for 57600
bits per second, 8 data bits, no parity, 1 stop bit and no flow control.
NOTE: Software (XON/XOFF) flow control is supported. However, it should not be used when using XMODEM.
5. Confirm the HyperTerminal settings and click OK.
6. Press Enter to display the serial menu. The Appliance Selection Menu will be displayed.
6. Press Enter to display the serial menu. The Appliance Selection Menu will be displayed.