CyberResearch UCERB 24 Manual De Usuario

Descargar
Página de 38
Unpacking the 
UCERB 24 
As with any electronic device, you should take care while handling to avoid damage from static 
electricity. Before removing the 
UCERB 24 from its packaging, ground yourself using a wrist strap or 
by simply touching the computer chassis or other grounded object to eliminate any stored static charge. 
If your 
UCERB 24 is damaged, notify CyberResearch, Inc. immediately by phone, fax, or e-mail. 
ƒ
  Phone: 
203.483.8815.  
ƒ
  Fax: 
203.483.9024 to the attention of Tech Support 
ƒ
  Email: 
techsupport@
cyberresearch.com
 
.
 
Installing the 
UCERB 24
The 
UCERB 24 has two on-board switches that you set to configure the relay logic polarity and the 
resistor pull-up/down configuration. Configure these switches before you connect the external power 
supply to the 
UCERB 24. Factory-configured default settings are listed in Table 2-1. Refer to Figure 3.1
 
for the location of each switch on the 
UCERB 24. 
Configuring the hardware switches 
The 
UCERB 24 has two on-board switches that you set to configure the relay control logic polarity and 
the 
relay 
power-on 
state
. Factory-configured default settings are listed in 
Table 2.1 Refer to Figure 3.1 for 
the location of each switch on the 
UCERB 24. 
Board labe
Default 
setting 
INVERT NON-INVERT 
S1 
Configures the relay control logic parity per relay bank for invert or 
non-invert logic. 
Non-invert 
Pull DOWN PULL UP 
S2 
Configures the relay power-on state per relay bank for pull-up or 
pull-down. 
Pull-down 
Table 2-1. Default switch configuration
UCERB 24  
 
CyberResearch
® 
Digital I/O 
 
6                                                                                                     ©Copyright 2005 CyberResearch, Inc.