Crestron electronic TPS-GA-TPI Manual De Usuario

Descargar
Página de 56
Isys
®
 G-Series Touchpanel Interface 
 
Crestron TPS-GA-TPI
 
24  
  Isys
®
 G-Series Touchpanel Interface: TPS-GA-TPI 
Operations Guide – DOC. 6501 
 
To open the QM AUDIO OUTPUT SETUP menu, press the QM Output button on 
the GENERAL AUDIO SETUP menu. The QM AUDIO OUTPUT SETUP menu 
offers a series of buttons that adjust the program gain and Transmit QM ID. 
The Restore Default Output Settings button returns all audio parameters on this 
menu to their default settings. Program Gain buttons and Transmit QM ID Manual 
and Auto buttons are provided to adjust QM audio output. After these parameters 
have been set, select the Return button to return to the SETUP MENU. 
QM AUDIO OUTPUT SETUP MENU 
 
Refer to the following table for additional QM AUDIO OUTPUT SETUP menu 
details. 
QM Audio Output Setup Details 
QM AUDIO 
OUTPUT SETUP 
SCREEN 
CONTROLS 
DESCRIPTION  
Restore Default 
Output Settings 
Returns the settings on this menu to their factory 
defaults. 
Program Gain 
This controls the volume of the QM Program audio sent 
to the QM output with the  and + buttons. 
Transmit QM ID 
Allows transmission of touchpanel’s QM ID for use in QM 
systems utilizing auto compensation*. Manual will 
transmit a specific QM ID, adjustable with the Down and 
Up Buttons. Auto, the default setting, will transmit the 
Cresnet ID as the QM ID. 
Auto compensation automatically recalls program gain settings when acting as an origination point.