 15
 
2.4 Erasing Transducer Setting 
When changing transducer(s), erase previous transducer setting(s) as shown below and 
then enter new transducer settings as in paragraph 2.2. (The set cannot transmit unless 
transducer settings are entered.) 
 
To erase transducer settings, do the following: 
 
1.  Turn on the power while pressing and holding down switch S1 (TDCLR) on the CPU 
board.  
2.  Release S1 when the TX/STBY LED flashes slowly.   
S1
02P6307
CPU
Board
TX/STBY
LED lamp
 
ETR-30N, cover removed