Country Flame HR-01 Manual De Usuario

Descargar
Página de 57
Version 
2.0b 
     
41
 
 
 
 
 
 
 
 
 
 
APPENDIX A:  TROUBLESHOOTING GUIDE 
Shut off the power to the unit and allow it to cool off when performing cleaning and maintenance. 
 
 PROBLEM 
SOLUTION 
Ignition 
The Stove power indicator does not 
flash red.  
Check the power supply. 
 
Stove does not switch on  
The starter fire in the firepot has not ignited or is 
not burning properly.  Using gloves carefully open 
the doors and relay the pellet fire.  Wait 8-10 
minutes for the pellets to burn well, before 
restarting the system. 
Fuel 
If Corn/Pellets contain a large 
amount of “fines” (foreign matter) or 
sawdust 
You may want to screen/sift Corn/Pellets before use 
if they contain a large number cob and stalk pieces. 
Check the heat exchanger area for buildup often to 
determine if any additional maintenance is needed.  
 
No fuel in Firepot 
The Auger needs to be primed, as it has run empty 
or has become blocked. The stirring rod can be 
manually rotated by holding in the “up” and 
“down” arrows on the control board at the same 
time.  The control board needs to be in the “off” 
setting. 
 
Hard build-up on the firepot base 
Sand in the pellets may cause “clinkering” (hard 
brittle deposits found in the bottom of the firepot). 
Screen your fuel to make sure that there is no sand 
or other foreign matter 
 
Blockage in the auger. 
If the corn is not feeding into the firepot at the 
normal rate the auger may need to be cleaned.  This 
may be due to fines in the fuel. 
Stove  
Performance  
If your stove is not working 
effectively 
You may be using the wrong fuel.  Check that you 
are using the correct fuel.  Either  
# 2 Yellow Shelled Corn  - with a moisture content 
of 14% or less (12% preferred) or  
Pelletized wood fuel  - with a maximum moisture 
content of 8% may be used.  Your Country Flame 
Dealer can advise on where to obtain this fuel. 
Do not use seed corn. 
 
If your stove is not generating 
enough heat 
Fines or dust in the corn can cause the unit not to 
burn properly or can cause a buildup in the drop 
tube and restrict the flow of corn. Clean the auger 
and fuel supply. 
 
Stove not performing effectively  
Clean the Heat Exchanger System, as it may be 
clogged and blocked. 
 
Stove not getting enough air 
Check to ensure that the fresh air intake is clear and 
unobstructed. 
 
Stove Heat not adjusting 
It takes 30 minutes for the stove to warm up before 
you can change setting on the temperature control 
 
Restricted flue gas flow 
Fly-ash will collect in the exhaust venting system 
and restrict the flow of the flue gases.  Incomplete 
combustion, such as occurs during start-up, shut 
down, or incorrect operation of the room heater will 
lead to some soot formation which will collect in 
the exhaust venting system. The exhaust vent 
should be checked frequently and cleaned at least 
once a season. 
 
Room Air Blower does not activate 
Please contact your Country Flame Dealer as your 
stove may need maintenance