Fujitsu IRMC S2/S3 Manual De Usuario

Descargar
Página de 426
196
 
 iRMC 
S2/S3
Power Management
System Identification LED
As long as the System Identification LED is on, the iRMC S3 will not 
enable 
0 Watt
 mode. 
Advanced Video Redirection (AVR)
If an AVR session is currently active, the iRMC S3 will not enable 
0 Watt
 mode. Once all AVR sessions have been finished (i.e, no AVR 
is active), the iRMC S3 will enable 
0 Watt
 mode. 
Remote Storage Server (RSS), Telnet/SSH Sessions
If an RSS session or an SSH/Telnet session is currently active, the 
iRMC S3 will not enable 
0 Watt
 mode. This prevents the remote 
interface connections to the iRMC S3 from being lost.
AC power fail
If an AC fail occurs and the PSU (Power Supply Unit) is in the 
0 Watt
 
mode or in the scheduled mode, the PSU will return to system 
standby. Depending on the power restore policy settings (see 
), the iRMC S3 determines whether the server is to be 
powered on. If the power restore policy is set to 
Always power off
, an 
AC fail will never result in 
0 Watt
 mode. 
0 Watt
 mode may be reached 
after the next system power on.
Scheduled
Enables 
0 Watt
 mode and also displays the 
0 Watt Technology 
Administration Window
. The 
0 Watt Technology Administration Window
 allows 
you to specify a time interval at which the PSU is awoken from 
0 Watt
 
mode and thus both remote management and Wake-on-LAN (WOL) can 
be used. 
Figure 108: Power Options page, 0 Watt Technology Administration window
Start Time
Defines the beginning (
hh:mm
) of the time interval.