Fujitsu IRMC S2/S3 Manual De Usuario

Descargar
Página de 426
iRMC S2/S3
 393
IPMI OEM Commands supported by the iRMC S2/S3
12.1.2.3 SCCI-compliant communication commands
I
Die SCCI-compliant communication commands require that the Agent 
Service is running under the OS. To execute the commands, the 
iRMC S2/S3 communicates with Agent which finally performs the action.
02 05 - System OS Shutdown Request
This command initiates shutdown of the server’s operating system.
02 06 - System OS Shutdown Request and Reset
This command initiates the shutdown of the server’s operating system and 
subsequently restarts the system.
Request Data
-
B8
NetFnlLUN: OEM/Group
-
02
Cmd : Command Group Communication
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
05
Command Specifier
Response Data
-
BC
-
02
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
Request Data
-
B8
NetFnlLUN: OEM/Group
-
02
Cmd : Command Group Communication
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
06
Command Specifier
Response Data
-
BC
-
02
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first