Fujitsu IRMC S2/S3 Manual De Usuario

Descargar
Página de 426
412
 
 iRMC 
S2/S3
Configuring the iRMC S2/S3 via SCCI and scripted configuration
12.2
Configuring the iRMC S2/S3 via SCCI and 
scripted configuration
This section provides information on the following topics: 
How to use an SCCI (ServerView Common Command Interface) compliant 
interface for configuring the iRMC S2/S3.
Scripted configuration of the iRMC S2/S3
12.2.1 iRMC S2/S3 configuration data
I
Please note that the interface described below is mainly for remote 
configuration and is not an SCCI implementation. It only uses the SCCI 
command and configuration definitions and the SCCI file format.
12.2.1.1 Overview
The iRMC S2/S3 stores internal configuration data in two separate sections of 
its NVRAM (Non-volatile RAM):
FTS-specific ConfigSpace data, which is addressed by the firmware via a 
fixed internal description table. 
Original, manufacturer-specific NVCFG data, which is accessed by offset 
definitions.
Some configuration data from the original NVCFG data is internally mapped by 
the firmware to be accessible via ConfigSpace access methods. For instance, 
DNS servers and DNS configuration of the iRMC S2/S3 can be accessed both 
via IPMI OEM LAN configuration parameters and via ConfigSpace. Both 
methods access the same low level data structures in the original NVCFG area.
Non-iRMC S2/S3-specific ServerView software components (e.g. the 
ServerView Agents or the Server Configuration Manager) in some cases also 
map standard IPMI related commands and configuration items, such as 
standard IPMI user configuration or IPv4 network configuration. This 
implements an abstraction level between the IPMI BMC layer and higher 
software levels.