Contec SEH-9450-LAS Manual De Usuario

Descargar
Página de 99
3. Hardware Installations 
 
 
 
 
14 
SEH-9450-LAS 
Serial Port Connector: COM1 / COM2 
Serial 1 (COM1), Serial 2 (COM2), are onboard serial ports of the product.    The following table shows 
the pin assignments of these connectors. 
Table 3.4. 
Serial Port Connector 
PIN No. 
RS-232C 
RS-422 
RS-485 
1 DCD TX- TX- 
2 RXD TX+ TX+ 
3 TXD RX+ RX+ 
4 DTR RX- RX- 
5  GND GND GND 
6 DSR N.C. N.C. 
7 RTS N.C. N.C. 
8 CTS N.C. 
N.C. 
9 RI N.C. 
N.C. 
COM1 / COM2 
1
6
5
9
 
10 N.C. N.C. N.C. 
CAUTION
 
 
For RS-485, TX+(pin 2) and RX+ (pin 3) must jumper together inside the D type connector.   
TX- (pin 1) and RX- (pin 4) is the same. 
 
RS-422 / RS-485 specifications 
Transmission system: Asynchronous, half-/full-duplex serial transmission conforming to 
RS-422/RS-485 
Baud rate : 115,200 - 50bps (programmable) 
Signal extensible distance: 1.2km Max. 
RTS#
R
D
1ΚΩ
JCOM1: 14-6
JCOM1: 15-6
SOUTB
6.2ΚΩ
6.2ΚΩ
4.7KΩ
4.7KΩ 4.7KΩ
4.7KΩ 4.7KΩ
4.7KΩ
10 5
6 1
 
Figure 3.1. 
RS-422 / RS-485