Adjusting Label Sensitivity
Overview:
The CS2000 will automatically adjust its label sensitivity, to the optimal setting, by 
simply depressing a push-button. This adjustment process is referred to as "Easy Setup." It is 
recommended that the operator adjust the label sensitivity for each new roll of labels due to 
differences in label rolls.
Easy Setup:
To  adjust label sensitivity for each new roll of labels follow steps 1-4.
1. Peel off a label and position the web (label backing) under the sensing area.
2. Depress the push-button until the yellow LED comes on (1 sec.), then release.
3. The yellow LED will begin flashing.
4. Move a label under the sensing area and the green LED will come on.
The sensor is now adjusted and should function correctly.
*Note: If in the Adjusting Label Sensitivity mode by mistake, the push-button may be 
depressed to exit with no changes made.
Possible Problems:
Red LED flashes after the 
push-button is released.
The sensor cannot adjust 
to the label backing. 
Probable cause is a build 
up of paper dust or some 
other obstruction is under 
the sensing area.
Blow out any paper dust 
present and remove any 
obstructions, labels, or 
label residue from sensing 
area (refer to page 15).
Symptom
Problem
Solution
Yellow LED continues flashing 
even after a label is placed 
under the sensing area.
There is not enough 
contrast between the label 
and the label backing.
Try the Low Contrast 
Setting. See Program 
Mode (page 12) for more 
information.