Connect Tech 104 Manual De Usuario

Descargar
Página de 26
Connect Tech FreeForm/PCI-104 User Manual 
 
Revision 0.00 
25
Table 11: Local Address Space 1 (Bar 3) 
Local Address 
Contents 
Access 
Description 
10000000 
SPI Command 
RW 
SPI controller command register, once command is written 
operation begins  
10000004 
SPI Parameters 
RW 
There are four parameters, each one byte 
-
 
0x04: Param0 
-
 
0x05: Param1 
-
 
0x06: Param2 
-
 
0x07: Param3 
10000008 
SPI Status 
SPI controller status register 
-
 
Bit 0: Operation complete 
1000000C 
SPI Result 
There are four results, each one byte 
-
 
0x04: Result0 
-
 
0x05: Result1 
-
 
0x06: Result2 
-
 
0x07: Result3 
10000010 –  
100000FC 
Un addressable 
N/A 
N/A 
10000100 – 
100001FC 
Dual port memory  RW 
256 Bytes of for flash page storage 
 
Implementation 
 Refer to the FreeForm/PCI-104 VHDL Reference Design Application Note for further information.