Technical Service Manual 
10 
 Window slider kit
minimum: 28 /8(72cm)
maximum:55 /8(140cm)
1
3
                         
1
3
 
                      Fig. 8.2                                                                            Fig .8.3 
3.  Select the best location 
z
  Beside the window, door or French window. 
z
  Keep the distance between the return air outlet and the wall or 
other obstacles to at least 20 inches (50cm) 
z
  Fix one end of the air hose on the air intake or outlet at the back of 
the unit. 
z
  Extend the air hose to the clearance between window, door, or 
French window, or wall hole. 
z
  Air outlet or intake should not be blocked by protective grid or 
objects. 
z
  The distance between two ends of the air hose should be kept at 
minimum of  8 inches (200mm) 
Note: the cooling capacity will decrease if only the air discharge  
hose is used, but air outlet temperature will be lower. 
 
Installation instruction 
z
  Air outlet or intake opening should not be blocked by curtain, or 
other objects. 
z
  Hose opening should not be block by shutters or other similar 
objects. 
z
  Do not bend the air hose when assembling; keep it straight as 
figure 3. 
z
  When operating in cool or dry mode, condensate will accumulate 
in the water tank. When the tank is full, water full indicator will 
light up (red) and LCD will display the sign E. The unit will stop 
operating.  
Shut off the power supply, pull out the rubber plug in drain port at 
the rear of the unit, drained the water into a container or other 
appropriate area. 
Note: water should be drained off when the water full light is on, 
otherwise, the appliance will not operate.