Cisco Systems 2140 Manual De Usuario

Descargar
Página de 116
3-21
Cisco Application Deployment Engine (ADE) 2130 and 2140 Series Appliance Hardware Installation Guide
78-18579-02
Chapter 3      Installing the Cisco ADE 2130 and 2140 Series Appliance
    Powering Up the Cisco ADE 2130 and 2140 Series Appliance
Power-Up Procedure (DC Power Supply)
To power up a Cisco ADE 2130 and 2140 Series appliance with a DC power supply and verify its 
initialization and self-test, follow this procedure. When the procedure is finished, the appliance is ready 
to configure.
If a redundant power supply is used, separate DC power sources are needed for each power supply. This 
allows you to turn off power for one power supply without affecting the power source for the other.
Step 1
Review the information in the 
Step 2
Plug the Molex terminal block connector into the power connector located on the rear right-hand side of 
the appliance. (See location 1 in 
Step 3
Connect the DC power input wires to the DC power source at your installation site.
Step 4
Press the power button on the front of the appliance. (See location 9 in 
The appliance should begin its powerup procedure. 
Step 5
After the operating system boots up, observe the front-panel LEDs to verify that your system is operating 
properly. (See 
.)
Once the operating system boots, you are ready to initialize the basic software configuration. (See the 
software installation guide or user guide that shipped with your appliance, for proper configuration 
procedures.)
Checking the LEDs
When the Cisco ADE 2130 and 2140 Series appliance is up and running, observe the front-panel LEDs. 
(See 
.)
Figure 3-13
Cisco ADE 2130 and 2140 Series Appliance Front Control Panel
1
Appliance power LED
6
ID control switch (push button)
2
Appliance status LED
7
NMI (nonmaskable interrupt) recessed 
button
1
3
Hard disk drive activity LED
8
Reset push button
4
NIC activity (all NICs)
9
Appliance power push button
5
Appliance system ID LED
A
B
C
D
E
H
F
I
G
1
2
3
4
5
6
7
8
9
231190