6500 Disk Array User’s Guide
21020690 B
Chapter 3   Display/Operation Panel
 
ARRAY INFORMATION
Page 3 - 15
ARRAY 
INFORMATION
From 
)81&7,21 6(/(&7, use the left/right arrow keys to select $55$<
,1)250$7,21 (see “Menu Structure (3 of 5—Array Info & Rebuild)” on page 
3-8)
. These display-only selections let you view the following array 
information:
),50:$5(
7(03(5$785( 6(16256
&$3$&,7<
,1,7,$725 ,1)250$7,21
0(*O0(7(5
FIRMWARE
The 
),50:$5( menu gives you access to three firmware parameters: firmware 
revision level (
),50:$5( 5(9); the results of a checksum test (7(67
&+(&.6806); and a display of the hexadecimal tallies of the checksum test 
(
',63 &+(&.6806).
FIRMWARE REV
Displays the revision level of the firmware residing in the array’s firmware 
PROM device. Two submenus display the date and time associated with the 
firmware revision, and a third submenu displays the model number of the array.
TEST CHECKSUMS
This item and its submenu display, as 
3$66 or )$,/, the results of a test in 
which expected checksums are compared to actual calculated checksums of the 
current contents of the Primary (PR) firmware buffers, and the BIST buffer. 
Matching checksums for a buffer verify that the contents of that buffer have 
not changed and it passes the test. 
DISP CHECKSUMS
This item is similar to the
7(67 &+(&.6806 item except that, instead of 
showing a 
3$66 or )$,/ condition, the actual checksums are displayed in 
hexadecimal. Two submenu items are associated with 
',63 &+(&.6806. In 
the second submenu item, there are four entries: at the upper left, the expected 
checksum from the primary buffer appears; at the lower left, the calculated 
checksum for the primary buffer is shown; at the upper right, the expected BIST 
checksum appears; and at the lower right, the calculated BIST checksum 
appears. 
TEMP
SENSOR
Displays the temperature detected by the sensor (on the controller board) in 
degrees Celsius and Fahrenheit.