General Teleworker VPN Client Settings
This section describes how to enable the Teleworker VPN Client feature, configure 
the Auto Initiation Retry settings, and manually connect or disconnect the VPN 
connections.
STEP 1
Click VPN > Teleworker VPN Client.
STEP 2
Enter the following information:
Teleworker VPN Client: Click On to enable the Teleworker VPN Client 
feature and hence set the security appliance as a Cisco VPN hardware 
client, or click Off to disable it. 
NOTE: Enabling the Teleworker VPN Client feature will disable the 
Site-to-Site VPN and IPsec Remote Access features and terminate their 
connected VPN sessions. 
Auto Initiation Retry: Click On to enable the Auto Initiation Retry feature, or 
click Off to disable it. 
When you enable Auto Initiation Retry, the security appliance (set as the 
Cisco VPN hardware client) first initiates the VPN connection to the primary 
server. If there is no response from the primary server after the timeout that 
you set in the Retry Interval field, the security appliance then re-initiates the 
VPN connection to the primary server. This continues for the number of times 
that you set in the Retry Limit field (or until the primary server is connected). 
If the primary server cannot be connected after the specified number of 
times, the security appliance tries to re-initiate the VPN connection to the 
backup servers by following the specified timeout and retry times. If all three 
backup servers cannot be connected, repeat the re-initiation process again 
and again until an IPsec VPN server can be connected. 
When you disable Auto Initiation Retry, the security appliance first initiates 
the VPN connection to the primary server. If there is no response from the 
primary server in 120 seconds, the security appliance then re-initiates the 
VPN connection to the backup servers. If all three backup servers cannot be 
connected, repeat the re-initiation process again and again until an IPsec 
VPN server can be connected. 
Retry Interval: Specify how often, in seconds, that the security appliance 
re-initiates the VPN connection to the primary server and the back servers. 
The default value is 120 seconds. 
Retry Limit: Enter the number of times that the security appliance will retry 