5-172
Axxius 800 - Release 2.2
CLI Commands
set
set (v54)
Use the set (v54) command to setup V.54 Loopback Test Parameters. The command specifies 
the range of channels within that card, and the setting to apply. 
Syntax:
set {v54-addr} v54 {setting} [off|on] [n] [nnn]
Example:
set 6:1 v54 equipment clear
The example will clear the loop test counter on the V.54 card in slot 6, port 1.
{v54-addr}
In the form of {slot:port}.
{setting}
slot
Slot number (1-8) of the Axxius chassis where the V.35/54 card is located
port
Port number or range.
equipment
Set the V.54 Equipment (Tx) parameters:
 address
Syntax: set {v54-addr} v54 equipment address {nnn}
Set V.54 loop test address [nnn]
Set the address to be tested.
[nnn] {nnn} must be one of the following:
0 - 255.1, 3, 5, 7, 9, 11, 13, 15,17, 19, 21, 23, 25, 27, 29, 31, 37, 39, 
43, 45, 47, 51, 53, 55, 59, 61, 63, 85, 87, 91, 95, 111, 119, 127, 255 
(255 disables). See chart below.
 clear
Syntax: set{v54-addr} v54 equipment clear
Clear the bit error rate counters during BER test
 ignoreack
Syntax: set{v54-addr} v54 equipment ignoreack 
{off|on}
Ignore V.54 ACK check [off|on]
Ignore acknowledge from remote equipment. This allows potential 
testing with non-compliant equipment by ignoring the acknowledge 
phase. WARNING: When choosing this option, the V.35 card 
will no longer be compliant with the V.54 specification. Use for 
debug purposes only.
 loopdown
Syntax: set{v54-addr} v54 equipment loopdown
Stop the test sequence
 loopup
Syntax: set{v54-addr} v54 equipment loopup
 Start the test sequence