Carrier Access Network Device Axxius 800 Manual De Usuario

Descargar
Página de 568
Axxius 800 - Release 2.2
8-3
 FXO 
Voice 
Card
Features
Features
l
Delivers FXO or DID telephone services from T1 access circuits
l
Supports CLASS services including caller ID, calling party disconnect and 
distinctive ringing
l
Provides up to 64 FXO or DPT voice lines in one Axxius 800 chassis, occupying 
just two rack units of equipment space (19 or 23- inch rack)
l
Complies with NEBS Level 3 standards for loop range and ringing protection for 
end office and customer premises
l
Offers fuseless overvoltage and overcurrent protection to minimize service calls 
from lightning and power cross incidents
Technical Specifications
Controller Software and Hardware Required
l
Release 1.1 or higher is required for the FXO Service card
l
-48V NI48V Power Supply (P/N 740-0084) is required for this card
FXO Transmission Performance
l
Return Loss: ERL > 26 dB, SRL > 18 dB with respect to 900
Ω + 2.16µ
F
l
Transhybrid Loss: ERL > 26 dB, SRL > 18 dB with respect to 900
Ω + 2.16µ
F
l
Idle Noise: A/D < 16 dBrnC0, D/A, 12 dBrnC0
l
Crosstalk Coupling: < 70 dB at 0 dBrn0
l
Signal/Distortion: > 35 dB with 1004 Hz, 0 dBm0 input
l
Overload: +3.0 dBm/900
Ω
l
Frequency Response: +0.3 dB -1.0 dB from 300 to 3400 Hz
l
Encoding: 
µ
-law 255 for U.S. and Canada as defined in CCITT G.711 and G.712
l
Terminating Impedance: 900
Ω
 + 
2.16µ
l
Transmit Gain/Loss: +7 to -9 dB, CLI selectable
l
Receive Gain/Loss: +7 to -9 dB, CLI selectable
l
Modem Support: Full compatibility with V.90 modems