11-3
Single Channel POTS Cards
Technical Specifications
Technical Specifications
Controller Software Required
l
Release 1.0 or higher is required for the POTS Service cards
FXS Transmission Performance
l
Return Loss: ERL > 28 dB, SRL > 20 dB with respect to 900
Ω + 2.16µ
F
l
Transhybrid Loss: ERL > 28 dB, SRL > 20 dB with respect to 900
Ω + 2.16µ
F
l
Idle Noise: A/D < 25 dBrnC0
l
Signal/Distortion: > 45 dB with 1004 Hz, 0 dBm0 input
l
Terminating Impedance: 900
Ω
 + 
2.16µ
l
Transmit Gain/Loss: +4 to -12 dB (in .25 increments)
l
Receive Gain/Loss: +4 to -12 dB (in .25 increments)
l
Overload: +3.0 dBm0
l
Frequency Response: +0 dB -1.0 dB from 300 to 3400 Hz
l
Longitudinal Balance: >50 dB
l
Modem support: full compatibility with V.90 modems
Modem Performance
l
The Single Channel POTS card modem is registered for direct connection to the 
PSTN
FXS Signaling Performance
l
DC Loop Range: 512 
Ω
l
Loop Feed: Nominal -48 VDC with 26mA current limit 
l
Ringing Voltage: 40 V rms, 20 Hz
l
Maximum Ringers: 2 REN, FCC Class B ringers
l
FXS Signaling: FXS loop start