V.35/.54 Card
Connector Pinouts
LEDs
Each V.35 port has an LED, with definitions as shown in the table below.
Sub-miniature 
DB-26 
Signal
Winchester 
34-pin (female)
Paired 
Signals
15
 Receive Clock A 
V
17
 Receive Clock B 
X
22
 Local Loopback 
J
25
 Remote Loopback 
BB
9, 13, 18
Open Pins/No Contact
L, N, NN
19, 21, 26
Open Pins/No Contact
State
Description
Off
No T1 Assignment
Green 
Normal (CD/RTS) Active
Red
CD inactive (T1-side failure)
Yellow
RTS inactive (equipment-side failure)
Flashing Yellow
Loopback toward T1 or equipment loop test
Flashing Green
Loopback toward equipment or network loop test