Carrier Access Network Device Axxius 800 Manual De Usuario

Descargar
Página de 568
Axxius 800 - Release 2.2
C-19
 Loopback 
Tests
V.35/V.54 Loop
V.54 Loop
Note: Local LED flashes yellow, remote LED flashes green.
Enable V.54 Loop
Where a V.35/V.54 card is in slot 6.
> set 6:1 v54 network enable
OK
View Status of Loopback   
> show 6:1
SLOT 6:
Settings for V35 Port 1:
     CTS:                    Always High
     Timing:                 Source
     Rx Clock Inversion:     Normal
     Tx Clock Inversion:     Normal
     Data Inversion:         Normal
     Data Speed:             64K
     Data Rate:              768 K
     V.54 Rx LB:             enabled
     V.54 Rx Addr:           255
     V.54 Test Addr:         255
     V.54 Tx Prep count:     15
     V.54 Rx Prep count:     15
     V.54 Test Pattern:      QRSS
     V.54 Ignore ACK:        OFF
     Loopback:               None
T1
Network
T1
Local
DTE
Axxius
Equipment
Unit
Local
DCE
V.35
Axxius
Network
Unit
Remote
DTE
Remote
DCE
V.54
Loopback
V.35