Cabletron Systems CSMIM-T1 Manual De Usuario
BOOT Failures
CSMIM-T1 Hardware Installation Guide
5-9
Activity TE2: Hardware Failure
The ROM diagnostics detected a CSMIM-T1 hardware problem requiring
service. Call Technical Support.
service. Call Technical Support.
Activity TE7: Booted Wrong Image
The CSMIM-T1 loaded an inappropriate image. Press the SETUP button
for three seconds to reset the device. Following is a list of ways to prevent
this problem in the future:
for three seconds to reset the device. Following is a list of ways to prevent
this problem in the future:
•
Be sure that you configure the CSMIM-T1 with the appropriate image
(
(
oper.46.enet
).
•
Be sure that the image you are booting has the right name. Don’t
rename the image file unless you are making a copy for safe keeping.
rename the image file unless you are making a copy for safe keeping.
•
If you used an na, admin, or cli boot command, specify the correct
image and a valid filename.
image and a valid filename.
5.3
BOOT FAILURES
The procedures for troubleshooting a power-up failure established that
•
The hardware is functional.
•
The Ethernet interface is functional.
•
The CSMIM-T1 can communicate with the Ethernet.
If the CSMIM-T1 still is not booted, you must pinpoint the problem. The
boot error report can help in this process.
boot error report can help in this process.
Generally, two problems cause boot failures:
•
The CSMIM-T1 is not configured properly.
•
The load server host is not responding.
NOTE
The CSMIM-T1generates a boot error report only if it opens the
boot file and an error occurs during the boot process.
boot file and an error occurs during the boot process.