Atmel AVR2070 Manual De Usuario
22
AVR2070
8240B-AVR-06/09
Table 5-2 AVR Serial Menu Commands
ASCII Command
Description
T
Touch. Ping or send a Reading (asks for ‘p’ or ‘r’ & interval time).
c
Channel. This allows the user to change the operating channel.
d
Dump. This shows the current content of the radio control registers.
i
Info. This provides a quick display of current radio settings including,
PANID, Channel, Short Address, etc.
PANID, Channel, Short Address, etc.
n
Name. Allows the user to set the name of a node – 11 characters
max.
max.
p (lowercase)
Ping. Ping a user selected node.
P (uppercase)
Pause. Pause or un-pause serial display (stop serial input).
r
Read interval. Allows the user to alter the interval at which the end or
router nodes will report data to the PAN Coordinator.
router nodes will report data to the PAN Coordinator.
t
Table. Display a table of nodes and their relationships.
s
Stream Mode. This will stream ASCII data between any two nodes in
the network provided each device has a serial connection to a host
PC.
the network provided each device has a serial connection to a host
PC.
Note: This only works for AVR based devices
w
Wake. If a node has been loaded with code that allows sleep
(SLEEP=1) then it must be woken up before it can respond to
commands such as “r”.
(SLEEP=1) then it must be woken up before it can respond to
commands such as “r”.