Atlas GUARDIAN PLMS Manual De Usuario

Descargar
Página de 4
2
598-1095-01
INSTALLATION
SPECIFICATIONS
Range . . . . . . . . . . .  Up  to  30  ft. (9.1 m)
[varies with surround-
ing temperature]
Sensing Angle . . . . .  Up  to  150
°
, 360
°
adjustable
Sensor Capacity . . .  Up to 360 Watts (3.0
A.) Maximum
Power Requirements 120 VAC, 60 Hz
Operating Modes . .  TEST, AUTO and
MANUAL OVERRIDE
Time Delay . . . . . . .  1 , 5, 20 minutes
Sensitivity . . . . . . . .  Adjustable
Dual Light Level . . .  3, 6 hours, Dusk-to-
Dawn
Atlas Lighting Products, Inc. reserves the
right to discontinue products and to change
specifications at any time without incurring
any obligation to incorporate new features in
products previously sold.
Twist the wires from the post and the
bottom sensor wires together as shown.
Secure with wire connectors provided.
Make sure the wires and connectors are
all inside the post, then set the sensor
onto the post.
Start and temporarily tighten the three screws
previously removed from the sensor.
Twist the wires from the fixture and the top
sensor wires together as shown. Secure with
wire connectors saved from your fixture.
Make sure all the wires and connectors
are inside the fixture/sensor wiring com-
partment. Set your coach light onto the
sensor and proceed to the adjustments
on the next page.
Turn power off at circuit breaker.
On existing installations, remove the light
from the top of the post. Keep the wire
connectors to make the connections to
the top of the sensor.
CAUTION:  When handling the sensor
be careful not to pinch or distort the lens.
You may break the seal and cause wind-
blown rain to enter the sensor.
Remove the three screws around the
bottom edge of the sensor. Save these
screws for later use.
Set the controls on the bottom as shown:
ON-TIME to TEST, Dual Light Level (AC-
CENT) OFF, and Sensitivity to mid-position.
TEST
20
5
1
DUSK TO DAWN
6 HOUR
3 HOUR
OFF
MAX.
Sensitivity
MIN.
ON TIME
MINUTES
ACCENT
Black sensor
wire to Black
post wire
White sensor
wire to White
post wire
White sensor
wire to White
fixture wire
Green sensor
wire to Green or
bare fixture wire
Red sensor
wire to Black
fixture wire
Green sensor
wire to Green or
bare post wire