Arturia MOOG MODULAR 2.6 Manual De Usuario

Descargar
Página de 154
82 
ARTURIA – MOOG MODULAR V 2.6 – USER’S MANUAL 
A  trigger  delay  module  manages  the  signals  used  for  triggering  envelopes  and  sequencer. 
There are 2 delays, which can function independently, in series or parallel following the setting 
on the “mode” selector. 
 
Set to the “off” position, the 2 delays are independent. When their trigger input moves to an 
active state, their internal counter is initialized. The output will move to an active state when 
their  internal  counter  reaches  the  value  specified  by  the  rotating  “time”  button.  When  the 
trigger input returns to an inactive state, the output immediately goes not an inactive state. 
 
Set to the “parallel” position, the 2 internal counters start at the same time when the trigger 
input  of  the  first  delay  goes  to  an  active  state.  Each  manages  its  output  in  function  with  its 
time setting. 
 
In the series position, the second counter only begins when the output of the first delay moves 
to an active state. 
 
 
Independent mode 
 
Parallel mode