Switches and Indicators
 
1.6
Switches and Indicators
 
 
Table 2. Switches and Indicators
 
Panel
Name
Description
 
Front
DATA FLOW 
(switch)
Determines how the ATM unit responds to a missing 
or invalid OC-3 input.
CONTINUOUS - Continues record and playback 
operations at 155.52 Mbits/sec as 
determined by an internal crystal 
oscillator. This provides a valid OC-3 
output during playback regardless of the 
OC-3 input status. 
GATED - 
Pauses record and playback operations 
until valid OC-3 input is restored.
The ATM unit resumes normal operation after the 
OC-3 input is restored.
TRANSMITTER
EMPTY 
(yellow 
indicator)
Indicates data rate from the tape drive is too slow. 
This is to be expected whenever the tape drive is not 
supplying data.
FULL 
(red indicator)
Indicates data rate from the tape drive is too fast. This 
is an abnormal condition and most likely indicates 
that the tape drive is not using its write input to 
regulate its playback rate (internal playback clock* 
should be disabled).
OK (green 
indicator)
Indicates correct data rate from the tape drive.
RECEIVER OK
(green indicator)
Indicates ATM unit receiving valid OC-3 optical 
signal input.
POWER (green 
indicator)
Indicates ATM unit is powered-up.
POWER (switch)
ON - Powers up the ATM unit.
OFF - Powers down the ATM unit.
Rear TEST 
LOOP 
(switch)
TEST - Self test operation.
NORMAL - Normal operation.
ERROR (red 
indicator)
Indicates (during normal operation) that a valid 
HOTLink input is missing.
RESET (button)
Resets the ATM unit during normal operation.
*For setting internal playback clock options, see DIS Tape Drive or ACL Installation and 
Operation manual.