Troubleshooting Guide 
Problem and 
Indication 
Possible Cause 
Corrective Action 
No power to unit. 
Power LED is off. 
Power cord is not 
properly connected.  
Verify power cord is properly connected to the BreezeNET unit 
and to the power outlet.  
Failure to 
establish wireless 
link. WIRELESS 
LINK LED is off. 
1. Power supply to units 
may be faulty 
2. The RB-DS.11 units 
may not have the same 
ESSID as the BU-
DS.11. 
1. Verify power to units. 
2. Verify that all units in the network have the same ESSID 
(ESSID must be identical in all units in the WLAN; the ESSID is 
case sensitive). Check that the units are on the same channel. 
3. Verify wireless link: 
Set BU-DS.11 and RB-DS.11 units side by side. 
Power on each unit and see if a wireless link is established (even 
“D” models without their external antennas should establish a link 
if placed side by side). 
If the units fail to associate, reset units to factory default values. 
The units should now establish a wireless link. 
Failure to 
establish wireless 
link (“D” 
models/external 
antennas) 
1. Power supply to units 
may be faulty. 
2. Cables may be 
improperly connected 
3. There may be some 
problem with antenna 
installation. 
1. Verify power to units. 
2. Verify that all cables are connected securely. 
3. Refer to previous Section and verify wireless link between the 
units. 
4. Verify that the antenna(s) are properly installed (see relevant 
section in this manual): 
 Check antenna alignment. 
 Verify that antenna polarization is the same at both ends.  
 Verify that the range matches specifications. 
 
  Verify line-of-sight/antenna alignment/antenna height.
 
Wireless link 
established, but 
there is no 
Ethernet activity 
(BU-DS.11 and 
RB-DS.11 units). 
1. Ethernet hub port or 
UTP cable is faulty. 
2. Ethernet port in unit 
is faulty.  
3. The RB-DS.11 is 
associated to a 
BU-DS.11 unit that is 
not connected correctly 
to the LAN. 
1. Check that the LINK LED is lighted Green. If this is not the 
case, the port is inactive. Try another port on the hub or another 
UTP cable. 
2. Verify that Ethernet port in unit is working. Ping unit to verify 
Ethernet connection. 
3. Verify that you are using a cross-over UTP cable (pins 1 & 3, 2 
& 6) if connected directly to a workstation, or a straight-through 
cable if connected to a hub.  
4. Check that the BU-DS.11 is correctly connected to the LAN.