ALTINEX MULTI-TASKER MT109-102 Manual De Usuario

Descargar
Página de 26
MULTI-TASKER™
400-0343-003
9
9
The Group ID is a number representing a group 
of cards defined with the [WR] command. 
When using the Group ID, all cards in the group 
will perform the given instruction.
Changing the position of a card will significantly 
affect the commands recorded on software 
definitions or third party control systems.
The Unit ID has a value from 0 to 9. Unit ID 0 
should be used for single unit operation. If the 
Unit ID is set to zero, each command may be 
used without Ui.  Use the command [SETU0], 
as explained in the MT100-100 User’s Guide.
Example:
[VERC3]:
For Unit ID Zero
[VERC3Ui]: For Unit ID other than Zero
[VERC3]:
Equivalent to [VERC3U0]
1.  [VER] 
This command displays the software version 
and card type for the MT109-102 card.
Command Format: [VERCnUi]
Cn = Card ID (n = slot # from 1 to max slots) 
Ui
= Unit ID (i = # from 0 to 9)
Example:
An  MT109-102  card is in slot #4. Send the 
command [VERC4], and the Multi-Tasker™ 
Enclosure will return the following feedback:
MT109-102  690-0133-008
MT109-102
= the card model
690-0133-008 = the software version
2.  
[C]
This command receives the status of the card.
Command Format: [CnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
There is one MT109-102 card in slot #4. 
 
Sending the command [C4]
to the 
Multi-Tasker™ will display feedback similar to 
the following:
In1Vol=16/16 
In2Vol=16/16 
In3Vol=16/16 
OutVol=16/16 
Bass  =08/16 
Treble=08/16 
Loudness:OFF
The status shows the input volume settings, in 
this case 16 out of 16, the output volume, the 
bass and treble levels and that the loudness 
feature is turned off.
If there is no card in slot #4, sending the [C4]
command will not return any feedback.
3.  [CnS]
This command saves the card volume settings. 
This configuration will be restored after the 
system is reset or powered off then on.
Command Format: [CnSUi]
Cn = Card ID (n = # from 1 to max slots)
S
= save configuration
Ui
= Unit ID (i = # from 0 to 9)
Example:
There is an MT109-102 in slot #4. All volume 
levels are set to the maximum of 16. The bass 
and treble levels are set to 08. Save the 
settings of the card by sending the command 
[C4S].  The feedback will be as follows:
In1Vol=16/16 
In2Vol=16/16 
In3Vol=16/16 
OutVol=16/16 
Bass  =08/16 
Treble=08/16 
Loudness:OFF 
Card Status Saved