4.  Set Ramp Time
Starting from the main menu, set the ramp time 
to 10 seconds. Follow the keystrokes below.
2
Select SETUP Menu
3
Select Set Ramp Time
4
Select Ramp Time = 10 seconds
ESC
Return to SETUP menu
ESC
Return to the MAIN Menu
5.  Display Card Status
Starting from the
Main Menu, follow the 
keystrokes below.
3
Displays card status
NOTE:
The status will be displayed, followed 
by the Main Menu being redisplayed.
TROUBLESHOOTING GUIDE
8
We have carefully tested and have found no 
problems in the supplied MT109-102; however, we 
would like to offer suggestions for the following:
8.1 LED IS NOT ON
Cause 1:
Card cage is not plugged into 
power outlet.
Solution: 
Plug card cage in. If the LED is ON, 
the problem is solved. If the LED is 
still not ON, see Cause 2.
Cause 2:
Card is not plugged in all the way.
Solution:
Push the card in all the way. If the 
LED is still not lit, see Cause 3.
Cause 3:
Card cage slot has a problem.
Solution 1: Test the card in other slots of the 
card cage. If the slot was damaged, 
the card may work in other slots. If 
other slots work, and the LED is 
ON, the problem is the card cage 
slot. The card cage may require 
service. Call ALTINEX at (714) 990-
2300. If the other slots do not work 
and the LED is still not lit, see 
Solution 2.
Solution 2: Take any other known good card 
with an LED and verify that the slot 
used is good by seeing if the other 
card’s LED lights in that slot. If it 
lights, then the original card may be 
the source of the problem. Call 
ALTINEX at (714) 990-2300.
8.2 NO SOUND
Cause 1:
The source has a problem.
Solution
Check the source and make sure 
that it is working at an appropriate 
volume level and all source 
connections are correct. If the 
source is working and there is still 
no sound, see Cause 2.
Cause 2:
The proper card input may not be 
selected.
Solution:
Select the card input that is used, 
by RS-232 accessible commands in 
section 7. If no sound is present, 
see Cause 3.
Cause 3:
Cable connections to the 
destination are incorrect.
Solution:
Make sure that cables are 
connected properly. Also, make 
sure that the continuity and wiring 
are good. If there is still no sound 
present, see Cause 4.
Cause 4:
The destination amplifier has a 
problem.
Solution 1: Make sure that the destination 
amplifier is powered. If there is still 
no sound, see Solution 2
Solution 2: Set the volume of the destination 
amplifier to a reasonable level. If 
there is still no sound, call ALTINEX 