INSTALLING YOUR  MT107-203
6
Step 1. Turn off power to the MultiTasker 
enclosure and remove the input AC power 
cord.
Step 2. Locate the MT107-104 currently installed 
in the MultiTasker.  Verify there is an 
empty slot in the enclosure for the new
MT107-203 card.
The empty slot must be directly to the left 
of the MT107-104 Matrix Engine. For 
example, if the engine is installed in slot 8, 
the input card should be installed in the 
first empty slot number less than 8.
Step 3. Route the ribbon cables through the notch 
in the add-on boards and connect to the 
MT107-104 base assembly using the 
special high-bandwidth cables provided 
with the engine.  Make sure the cable 
connector is secured in the socket of the 
input connector card.
Step 4. Attach the opposite end of the ribbon 
cable to the card and carefully slide the 
MT107-203  into  the empty slot in the 
MultiTasker enclosure. 
Step 5. Secure the card by tightening the retainer 
screws at the top and bottom.
Step 6. Connect the output of a Twisted Pair 
transmitter to the inputs of the MT107-203
using ALTINEX’s special cable part 
number MS8704TP.
Step 7. Restore AC power to the enclosure.
Step 8. The  MT107-203
is now ready for 
operation.
OPERATION
7
7.1 RS-232 CONTROL 
The 
MT107-203
has many advanced 
remote-control capabilities as part of an 
MT107-104 Matrix Switcher. These capabilities 
are accessible through standard RS-232 
communication. The actual controlling can be 
accomplished through a computer control 
system or any other device capable of sending 
RS-232 commands.
7.2 DESCRIPTION OF COMMANDS
Please see the MT107-104 User's Guide for a 
full listing of commands available for the 
MT107-203 as part of a MultiTasker Matrix 
Switcher.
TROUBLESHOOTING GUIDE
8
We have carefully tested and found no problems in 
the supplied MT107-203. However, we would like to 
offer suggestions for the following:
8.1 NO DISPLAY
Cause 1:
The source has a problem.
Solution:
Check the source and make sure 
that there is a signal present and all 
source connections are correct. If 
the source is working and there is 
still no display, see Cause 2.
Cause 2:
The input signal is not detected.
Solution 1: In 
AVSnap
®
, or other control 
software, send the [SDI] command. 
This command is detailed in the 
MT107-104 User’s Guide. Verify a 
signal is detected for the input 
number in question. If a signal is not 
detected, see Solution 2.
Solution 2: Verify the MT107-203 is connected 
to the MT107-104 and that the cable 
is in good condition. If a signal is 
detected, see Cause 3. If there is no 
signal detected, please
call
ALTINEX at (714) 990-2300.