SAFETY 
INTRAC-305
 
 
 
Page  10 
INTRAC-305 MANUAL  -  Issue 3.2  
© Advantech AMT Ltd 
 
1. 
SAFETY 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ELECTRICAL 
 
 
 
 
Fusing 
The standard unit is protected by a user replacable fuse in the 
live/phase power supply line. 
 
 
 
Care should be taken to ensure that the power cable is 
correctly connected to the power source such that the 
live/phase connection of the INTRAC is connected to the 
live/phase terminal of the supply. 
 
 
 
When replacing the fuse be sure to do so with one of the 
correct value and type. 
 
 
 
 
 
The Dual Redundant power supply version is protected by 
separate board mounted fuses on each power supply.  These 
are not user replaceable. 
 
 
 
Earthing 
It is important that the electrical supply has a good and proper 
earth and that earth is connected through to the INTRAC-305 
via the power cable. 
 
 
 
Battery Disposal 
The processor board contains a Nickel Cadmium (NiCd) or 
Lithium battery.  These elements are toxic.  The battery 
should be disposed of according to national requirements.  
DO NOT PLACE IN NORMAL GARBAGE OR IN A FIRE. 
 
 
 
RF I/P Connector for IBR-L 
18Vdc may be present on the inner of the N-Type connector 
to power the LNB/BDC.  This voltage can be removed by 
unplugging connector J41.  
 
 
 
Emergency Stop 
There is a latching emergency stop switch on the INTRAC 
front panel.  Pressing this switch will remove power from the 
antenna drive motors and the INTRAC will enter Standby 
mode.  To restore drive the switch should be rotated 
clockwise (CW) and Auto Continue selected.  
WARNING
 
 
POSSIBLE LETHAL POTENTIALS EXIST WITHIN THIS EQUIPMENT 
 
THE COVERS SHOULD NOT BE REMOVED EXCEPT BY QUALIFIED PERSONNEL. 
SWITCH OFF POWER AND ISOLATE SUPPLY BEFORE REMOVING COVERS.  
IF IT IS NECESSARY TO OPERATE THE EQUIPMENT WITH THE COVERS 
REMOVED FOR SERVICING PURPOSES ALL NECESSARY PRECAUTIONS 
SHOULD BE TAKEN TO PROTECT AGAINST ELECTRIC SHOCKS