3
 
FITTED OPTIONS 
 
Beacon Receiver: Fitted
Beac pol select: Not Fitted
Polarization   : Fitted
Mount    Az/El : Fitted
 Type HrAng/Dcl: Not Fitted
Resolver x2    : Fitted
 Type    x1    : Not Fitted
         
Extended Az    : Not Fitted
Geared Pol     : Not Fitted
SimAx Drive    : Fitted
Inv Beacon Lock: Not Fitted
1
2
3
4
5
6
(not used)
toggles the highlighted parameter
between Fitted/Not Fitted
resets the menu to display the currently
stored values
moves the highlight box to the next field
in the current menu
Current Mode     Tracking
Control State    Local
Beac Freq      11.452000 GHz
Beac Level    -10.05     dB
El   Angle     25.37
Az   Angle    210.50
Pol  Angle     27.4   
Function
Press EN to accept all fields
Next 
Field
Fitted/
Not
Home
Standby
puts the antenna control system into
STANDBY mode and skips to the HOME
menu
skips to the Home (root) menu
Recall
Existing
Settings
 
 
 
 
Path 
 
HOME - FUNCTION - SYSTEM SETUP -  
 
 
 
 
MENU KEY 6 (x6) - ENTER 
 
 
 
or 
From Models or Configuration 
 
 
 
 
SYSTEM SETUP - MENU KEY 6 (x6) - ENTER 
 
 
 
Description 
 
Various options such as polarisation drive and simultaneous 
axis drive are available on the INTRAC-305.  Their use has to 
be programmed into the INTRAC in order for them to be 
usable.  That programming is carried out in this menu. 
 
 
 
 
 
 
The various options are shown on this screen.  
  
 
 
 
Menu Key 6 (Next Field) steps the highlighted edit line 
through the options.   
 
 
 
 
Menu Key 4 (Fitted/Not) toggles the option between fitted and 
not fitted. 
 
 
 
 
Menu Key 5 (Recall Existing Settings) resets the options to 
the state they were in when this menu was entered. 
 
 
 
 
Pressing ENTER accepts the displayed settings. 
 
 
 
Note 
Beacon Pol Select, Extended Az, Geared Pol, and Inv 
Beacon Lock should be set to “Not Fitted”. 
 
 
 
 
SimAx Drive should be set to “Fitted”. 
 
 
 
 
Normally, when replacing an APC300, the correct resolver 
type will be x2.