Advantech INTRAC-305 Manual De Usuario

Descargar
Página de 96
 
INTRAC-305  
ALARMS & ERRORS      
 
© 2011 Advantech Wireless
 
INTRAC-305 MANUAL  -  Issue 3.2 
Page  51 
 
4
 
POWER FAILURE 
 
The INTRAC incorporates non-volatile memory and a battery 
backed real time clock.  The onset of a power failure is 
detected and the current mode is stored before the processor 
ceases to operate.  When power is restored the INTRAC 
performs an automatic recovery as below :- 
 
 
If the unit was in Auto (Tracking) Mode at the time of the 
power failure and no Primary Alarms have become active the 
unit will resume tracking.  The antenna will be moved (if 
necessary) to the current satellite position based on the orbit 
model and the real time clock. 
 
 
 
If the unit was in Auto (Learning) Mode it will resume in that 
mode.  However whether it continues learning or re-starts to 
learn depends on the ratio of the completed learning time to 
the period without power.  (i.e. how dependable the learnt 
orbit will now be) 
 
 
 
If the INTRAC was in any other Mode or if a Primary Alarm 
had occurred the unit will power up in Standby Mode with a 
power-up alarm. 
 
 
ERRORS
 
 
Errors are user errors and involve the entry of non valid data. 
 
 
 
Where data is entered outside the allowable limits for that 
data such as setting the beacon frequency outside the range 
of the selected band.  The entered data is changed to the limit 
nearest to the entered value and marked with an asterisk (*).  
On the bottom of the screen the message :- 
 
 
 
 
“ENTRY ERROR!, limits forced =*” 
 
 
 
is displayed. 
 
 
 
The forced limit data may be accepted by re-pressing the 
ENTER key or the correct value keyed in. 
 
 
IESS-412 DATA 
 
Where IESS-412 data is entered with the incorrect 170hr 
checksum the checksum is corrected by INTRAC in the same 
manner as above.  However it is up to the user to ascertain 
that it was the checksum which was wrong and not that wrong 
value data was entered.