Advantech INTRAC-305 Manual De Usuario

Descargar
Página de 96
 
INTRAC-305  
TECHNICAL DESCRIPTION 
 
© 2011 Advantech Wireless
 
INTRAC-305 MANUAL  -  Issue 3.2 
Page  59 
 
5
 
strength is recorded and at the end of this phase the antenna is 
driven to that position and the INTRAC enters Standby. 
 
 
At this point the peak may be confirmed manually and/or 
learning mode entered by selecting Auto New Model. 
 
 
Remote 
 
Remote Mode transfers control of the INTRAC to a remote 
terminal. 
 
 
It is selected with Menu Key 6 (Select Remote) from the Home 
menu.  Once in Remote Mode only four functions are available 
from the INTRAC front panel.  The emergency stop switch will 
inhibit the antenna drive as normal, the alarms can be 
displayed, Standby Mode can be entered and control can be 
returned to the front panel again with Menu Key 6 (Select 
Local). 
 
 
USING IESS-412 OR NORAD DATA 
 
 
 
The INTRAC-305 can make use of Intelsat IESS-412 11-
parameter or NORAD ephemeris information in two ways. 
 
 
 
1. 
The information can be used by the INTRAC to 
 
generate an INTRAC model of the satellites orbit.   
 
 
This model is then be used by the INTRAC as it would 
use a model it had learnt itself.  This means that there 
is not the need for the 24hr learning period.  The model 
is then updated as any INTRAC model would be. 
 
2. 
The INTRAC can 
be commanded to Program Track using positions 
calculated from the ephemeris data.  
 
 
 
 
 
The IESS-412 and NORAD data sets can be entered either 
manually from the INTRAC front panel or from a PC.  A stand 
alone program is available for loading the data file from a PC.  
This program can be used alone or in conjunction with the 
Remote Control Terminal RCM-4. 
 
 
A description of this program is given the appendices. 
 
 
The IESS-412 data 
 
The IESS-412 data set comprises 21 fields of data  :- 
 
 
 
IESS Epoch Year 
range: 80 to 99  (20th century) 
 
 
 
 
                00 to 79 (21st century) 
 
 
 
IESS Epoch Month 
range: 1 to 12 
 
 
 
IESS Epoch Day 
range: 1 to 31 
 
 
 
IESS Epoch Hour 
range: 0 to 32 
 
 
 
IESS Epoch Minute 
range: 0 to 59 
 
 
 
IESS Epoch Second 
range: 0 to 59