Serial Port RS422/423 Setting   
Setting the Serial Ports to RS422 or RS423 is achieved by 
positioning the rear panel ribbon cables and by link positions. 
The table below shows the positions. 
 
 
 
INTRAC
TM
 305 Serial Port Configuration - Connector & Link Positions
 
 
 
 
 
RS423  
 
RS422  
 
 
Ribbon Cable 
position. 
 
Link Position 
 
Ribbon Cable 
position. 
 
Link Position 
 
Test Port 1 
 
J12 
 
J44 Front 
 
J15 
 
J44 Rear 
 
Test Port 2 
 
J11 
 
J46 Front 
 
J14 
 
J46 Rear 
 
 
Serial Port  Usage 
 
The three ports can be used to connect a Remote Control  
Terminal, to monitor diagnostic data or to monitor angle data.  
The specific uses for each port are:- 
 
 
Remote Port 
A Remote Control and Monitoring Terminal may be 
connected to this port.   
 
 
Diagnostic data can be monitored by selecting “Diagnostics 
On” in the “Function - Configuration” menu.  Remote control 
of the INTRAC is achieved only if “Diagnostics Off” is selected 
in the Configuration menu. 
 
 
Test Port 1 
Diagnostic data is also available at this port together with 
Angles data.  The selection between Diagnostics and Angles 
is made by Menu Key 4 on the “Function - Configuration” 
menu.  The key switches between “Test Port-1 Diags” and 
“Test Port-1 Angles” 
 
 
Test Port 2 
This port is for a Remote Control Terminal only. 
 
 
 
The Remote Port allows one PC to be used as a remote 
control unit and as a diagnostics monitoring unit.  However it 
cannot do both at the same time. 
 
 
Note 
For correct remote control of the INTRAC-305 via the 
Remote Port Diagnostics must be set to OFF.  
Diagnostic 
data can be monitored during remote operation by using a 
second PC connected to Test Port 1. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INTRAC-305
 
Serial Port