ADIC Time Clock 6-00028-01 Rev A Manual De Usuario

Descargar
Página de 446
Managing the AMASS File System
6-00028-01 Rev A
Command Reference
3-77
Disable Feature for A Drive-Succeeds
In the following example, we set the drive to zero timeout; the 
idle eject feature will be disabled for the specified drive. 
Disable Feature for A Drive-Fails
In the following example, we set the drive to zero timeout; but 
the idle eject feature will not be disabled. 
Note
This example assumes the global 
IDLETIME
 parameter has been 
set to zero also.
# drivestat -e 0 1
Setting Idle Eject value for drive 1, juke 1, 
from 480 to 0 seconds. OK [y/n]? y
Drive 1, in juke 1, will not eject idle volumes 
(feature disabled).
Note
This example assumes the global 
IDLETIME
 parameter has been 
set to 31 seconds.
# drivestat -e 0 1
Setting Idle Eject value for drive 1, juke 1, from 
480 to 0 seconds. OK [y/n]? y
Drive 1, in juke 1, will eject idle volumes after 
31 seconds (global idletime).