5.4 Accessories 
The following accessory items can be used with the model 9210 / 9230 slide gate operator. 
 
Contact Sensor 
Contact sensors for use as a secondary entrapment protection device. 
Miller Edge, Inc.  ME120, ME123, MG020, MGR20, MGS20 
Photo Cell 
Non-contact (photo cells) sensors for use as a secondary entrapment 
protection device – Listed to UL 325. 
 
Infrared Thru-Beam with hood and built-in heater.  165-foot range. 
P/N 8080-010 
 
Photo-Reflective.  30-foot range. 
P/N 8080-011 
 
Infrared Thru-Beam.  65-foot range. 
P/N 8080-031  
 
Poloraized Photo-Reflective.  35-foot range. 
P/N 8080-030 
Loop Detector 
Detectors plug directly into ports on circuit board simplifying wiring. 
P/N 9410-010 - Single channel detector. 
P/N 9409-010 - Two channel detector 
Loop Wire 
18 AWG loop wire with XLPE insulation is ideal for ground loops.  
Available in 500 and 1000 foot rolls with red, blue or black insulation. 
Pre-Fab Loops 
Prefabricated ground loops.  24-foot circumference with 50-foot lead-in.  
Available in yellow, red or blue jackets.  Not for use in asphalt roadways. 
Loop Test Meter 
Meg-ohm meter checks the integrity of ground loops. 
P/N 9401-045 
Control Station 
Three button interior and exterior control stations provide manual open-
close-stop gate operation.   
P/N 1200-006 – Exterior / Interior 
P/N 1200-007 - Interior 
Time Clock 
7 day and 365 day time clocks can be used to automatically open gate at 
pre-set time and days. Compact clock fits inside the operator. 
P/N 2600-791 – 7-day clock.   
P/N 2600-795 – 365-day clock. 
Surge Devices 
High and low voltage surge suppressers help prevent circuit board failure 
caused by lightning strikes and power surges. 
P/N 1876-010 - High Voltage.   
P/N 1878-010 - Low Voltage. 
Gate Scale 
Use to test ft/pounds required to move gate.  P/N 2600-225 
Speed Bumps 
Prefabricated six-foot speed bump reduces traffic speed through gate 
system.  P/N 1610-150 
Mounting Stand 
Heavy-duty pedestal mounting stand for the 9210 operator. 
P/N 9200-135 
Remote Reset 
Remote reset control station includes both audio and visual alarms to 
indicate gate operator is in a hard-shutdown condition.  Also provides a 
reset button to reset the operator. 
P/N 1404-080 
Traffic Signal 
Red / Green traffic signal is synchronized with the movement of the gate 
and alerts drivers when it is safe to proceed. 
P/N 1603-208 
 
 
9210-065-H-8-08  
Page 
49