Desa VVDR30 Manual De Usuario

Descargar
Página de 28
www.desatech.com
124183-01B
14
GAS SHUTOFF
VALVE OPERATION
Flame Adjustment
Adjust the flame ON/OFF by turning gas shut-
off valve counterclockwise 
 to open or 
clockwise 
 to close, as necessary.
Shutting Off Appliance
Turn  gas  shutoff  valve  clockwise 
  to 
OFF position.
CURING 
LOGS
During the 2-3 hour appliance break-in period, 
you may detect an odor from the appliance 
as  various  paints  and  compounds  used  in 
manufacturing of this log set cure. This is a 
normal  and  temporary  situation  that  is  not 
cause for alarm. However, you may want to 
provide extra ventilation to the room during 
this time.
To ensure proper curing of the logs:
•  Ignite  a  2"  flame  and  maintain  it  for  1 
hour.
•  Burn logs in consecutive 1 hour periods 
raising the flame an additional 2" to full 
flame height for a total of three hours.
OPERATING
INSTRUCTIONS
FOR GA9050A-1
Note: Operation instructions for GA9050A-1 
Remote Ready Valve/Pilot Kit will be included 
with the kit.
1.  STOP!  Read  the  safety  information, 
column 1.
2.  Make sure equipment shutoff valve is fully 
open.
3.  Press in and turn control knob clockwise 
 to the OFF position.
4.  Wait five (5) minutes to clear out any gas. 
Then  smell  for  gas  around  log  set  and 
near floor. If you smell gas, STOP! Refer 
to  the  National  Fuel  Gas  Codes, ANSI 
Z233.1/NFPA 54, Air for Combustion and 
Ventilation
. If you don’t smell gas, go to 
the next step.
5.  Turn  control  knob  counterclockwise 
 to the PILOT position and press 
in. Keep control knob pressed in for five 
(5) seconds.
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: Keep flue open
when operating unit.
 WARNING: If you do not fol-
low  these  instructions  exactly,
a  fire  or  explosion  may  result
causing property damage, per-
sonal injury or loss of life.
BEFORE LIGhTING smell all around the ap-
pliance area for gas. Be sure to smell next
to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not
use any phone in your building.
•  Immediately call your gas supplier from
a  neighbor’s  phone.  Follow  the  gas
supplier’s instructions.
•  If  you  cannot  reach  your  gas  supplier,
call the fire department.
LIGHTING 
 INSTRUCTIONS
1.  STOP!  Read  the  safety  information, 
above.
2.  Turn gas shutoff valve to OFF.
3.  Wait five (5) minutes to clear out any gas. 
If you then smell gas STOP! Follow the 
safety  information,  above.  If  you  don't 
smell gas, go on to the next step.
4.  Light  a  match  and  lay  it  on  top  of  pan 
material about 2" from end of supply side 
of pan
5.  Slowly  turn  gas  shutoff  valve  ON  until 
burner  ignites.  If  burner  doesn’t  ignite 
within  10  seconds  with  match  burning, 
turn shutoff valve OFF and repeat steps 
1 through 4 again.