DeviceNet Network Scanner DVPDNET-SL
 
DVP-PLC Application Manual 
18
Slave  → DVPDNET-SL 
Register in 
DVPDNET-SL 
 
Devices in slave 
D6037H 
DI/DO module
X0 ~ X7 on DVP-16SP 
D6037L N/A 
D6038H 
Status of LED on VFD-B 
D6038L 
Status of VFD-B 
D6039H 
High byte of frequency in VFD-B 
D6039L 
 
AC motor drive
Low byte of frequency in VFD-B 
„ 
If the I/O data include control word and status word of RTU-DNET, the I/O data mapping of 
DVPDNET-SL and its slave devices will be:
 
DVPDNET-SL  →    slave 
Register in 
DVPDNET-SL 
 
Devices in slave 
D6287H 
High byte of control word in RTU-DNET
D6287L 
RTU-DNET 
control word 
Low byte of control word in RTU-DNET
D6288H 
DI/DO module
Y0 ~ Y7 on DVP-16SP 
D6288L N/A 
D6289H 
High byte of command in VFD-B 
D6289L 
Low bye of command in VFD-B 
D6290H 
High byte of frequency in VFD-B 
D6290L 
 
AC motor drive
Low byte of frequency in VFD-B 
Slave  → DVPDNET-SL 
Register in 
DVPDNET-SL 
 
Devices in slave 
D6037H 
High byte of status word in RTU-DNET
D6037L 
RTU-DNET 
status word 
Low byte of status word in RTU-DNET
D6038H 
DI/DO module
X0 ~ X7 on DVP-16SP 
D6038L N/A 
D6039H 
Status of LED on VFD-B 
D6039L 
Status of VFD-B 
D6040H 
High byte of frequency in VFD-B 
D6040L 
 
AC motor drive
Low byte of frequency in VFD-B 
3.  Saving the configuration data 
Select “File” => “Save” to save the current network configuration. 
5.3 DeviceNet 
Network 
Control 
In this section, we will introduce how to compile WPL program and control DeviceNet. The example given 
below is particularly for I/O data excluding RTU-DNET control word and status word. You will have to slightly 
modify the example program if the I/O data include RTU-DENT control word and status word. 
Target 
When X0 = On, VFD-B will start to run, and Y0 indicator will be On. 
When X1 = On, VFD-B will stop, and Y0 indicator will be Off.