Chapter 3 Creating and Editing Screens 
 
Example 
CALL
RET
Main
Macro
Sub-Macro
A1
 
The rights of macro control will be transferred to sub-macro when executing CALL 
Var1 command. After CALL Var1 command is executed and completed, Var1 needs 
to return through RET command. RET command will transfer the rights of macro 
control to the next command of CALL command. The sub-macro number could be 1 
~ 512. Regarding the comment name of the sub-macro, the user can name it freely. 
In the sub-macro program, the users also can CALL another sub-macro but the levels 
for CALL submacro should be less than 6 levels due to memory limit and also for 
avoiding unexpected error. 
 
 
FOR…NEXT (Program Loop) 
Equation 
FOR Var1 Statement NEXT  
 
Explanation 
It is for nested loops. ”FOR” is the start of the loop and “NEXT” is the end of the loop. 
When this command is executed, the number of Var1 Statement will be executed 
continuously. The users can change the Var1 value through command, but the 
number of times cannot be changed. 
 
Remark 
 
The nested loop can be up to 3 levels max.   
 
Var1 can be internal memory or constant. 
 
Statement is the combination of a section of macro commands and also can be 
within the nested loop. 
 
Example 
  If $10=10, $0=0, after the operation, the result is $0 = 10 
If a $10 = 2 is inserted between the FOR and the NEXT in the above macro, the FOR … 
NEXT loop will still loop 10 times even though $10 is changed to a value of 2 the first 
pass through the loop. 