Chapter 3 Creating and Editing Screens 
3.3 Internal 
Memory 
There are six kinds of registers for selection. They are internal register $, Non-volatile Internal 
Register $M, Indirect Address Register *$, Recipe Number Register RCPNO, Recipe Group 
Register RCPG and Recipe Register RCP (Fig. 3-3-1). For more details on settings, please refer to 
the following descriptions.   
 
Fig. 3-3-1 HMI Internal Memory 
3.3.1  Internal Register (Read / Write) : $ 
Word Access :  $n    ( n : 0-65535 ) 
Bit Access      :  $n.b( n : 0-65535, b : 0-15 ) 
Delta DOP-B series HMI provides 65536 16-bit internal registers ($0.0 - $65535.15). 
Note: The setting values of this register are not retained when power is off. 
 
Non-volatile Internal Register (R/W): $M 
Word access:   $Mn (n:    0~1023) 
Bit access:   
$Mn.b (n:    0~1023, b: 0~15) 
Delta DOP series HMI provides 1024 16-bit non-volatile internal registers ($M0 ~ $M1023). 
 
3.3.2  Non-volatile Internal Register (Read / Write) : $M 
Word Access :  $Mn     ( n : 0-1023 ) 
Bit Access      :  $Mn.b( n : 0-1023, b : 0-15 ) 
Delta DOP-B series HMI provides 1024 16-bit non-volatile internal registers($M0.0 - 
$M1023.15). As the setting values of this register are retained when power is off, the user 
can use this register to store the important data or records. 