Check SIM Sensor Connections
6
Connect the Anemometer Cable to the SIM
1. Unwind the coil of cable enough to work with the anemometer. 
Note: 
Do not unwind the entire coil of anemometer cable at this time.
2. Pull the foam insert out of 
cable access port in 
between the cables and set 
the foam insert aside.
3. Insert the anemometer 
cable end into the cable 
access port from beneath 
the SIM box.
Slide the cable through the 
cable access port with the 
connector lever down. 
4. Firmly insert the end of the 
anemometer cable into the 
connector labeled WIND. 
The lever clicks into place.
5. Make sure that the cables 
lie flat on the bottom the 
cable access port.
6. Firmly insert the foam in 
between the cables and at 
the top of the cable access 
port, taking care to ensure 
that the foam seals the 
access port entirely, leaving no holes or gaps large enough for weather or insects.
Note: 
If you are assembling a cabled station, wait to reinsert the foam until cable assembly is com-
plete. See “Cabled ISS Assembly” on page 7.
Once the sensor connections have been checked and the anemometer cable has been 
inserted, a connection between the ISS and the Vantage Pro2 console must be made. 
7. Read the following instructions that best apply to your ISS and Vantage Pro2 assem-
bly:
• See “Cabled ISS Assembly” on page 7 for assembling Vantage Pro2 weather sta-
tions that contain a cabled connection between the ISS and the console.
• See “Wireless ISS Assembly” on page 9 for assembling Vantage Pro2 weather sta-
tions that use a wireless connection to transmit and receive data.
Foam
Insert
Sensor
Interface
Module
(SIM)
Note: Only Plus models have UV and 
solar cables already attached.
07395.249 Manual ISS Installation_RevE_Final_Print.pdf   8
4/7/2008   1:44:48 PM