Marine Electrical Products
Features
 
•  
Switches 2 - 120V AC Sources or 2 - 230V AC Sources
  •  
Compact solution when circuit protection is provided elsewhere
•  
Allows connecting one of two different AC sources to one circuit
  •  
Heavy duty industrial rated switches
  •  
Intuitive function - One handed operation
  •  
UL listed switches
Specifications
 
Amperage Rating:   PN 9009 is rated for 32 amp maximum service
 
PN 9011 is rated for 65 amp maximum service
Voltage Rating:  
600 Volts AC Maximum
Maximum Wire Size: PN 9009 
10 AWG
 
PN 9011 
6 AWG
Minimum Wire Size:  PN 9009 
14 AWG
 
PN 9011 
12 AWG
Terminal Recommended Torque:
 
PN 9009 
12 lb-in.
 
PN 9011 
40 lb-in.
Inches
Millimeters
Overall Dimensions:  PN 9009 
1.890 x 1.890 
48.00 x 48.00
 
PN 9011 
2.520 x 2.520 
64.00 x 64.00
Mounting Depth: 
PN 9009 
1.913 
 
48.60
 
PN 9011 
2.807 
 
71.30
Maximum Panel Thickness: 
0.157 
 
4.00
 
Blue Sea Systems Inc.
Phone (360) 738-8230
425 Sequoia Drive
Fax (360) 734-4195
Bellingham, WA 98226 USA
www.bluesea.com
6670 Rev 002
WARNING
    These instructions are intended to provide assistance with the  
 
 
installation of this product, and are not a substitute for a more  
 
 
comprehensive understanding of electrical systems. We strongly    
 
recommend that a competent electrical professional perform the    
 
installation of this product.
  If either the switch front or back is to be exposed to water it must be  
 
protected with a waterproof shield. 
  The switch must not be installed in explosive environments such as  
 
gasoline engine rooms or battery compartments as the switches    
 
are not ignition proof. 
  The vessel’s shore power cord must be disconnected form shoreside  
 
power before installing this electrical switch.
  If an inverter is installed on the vessel its power leads must be    
 
disconnected at the battery before the panel installation. Be aware that  
 
many inverters have a “sleep mode” in which their voltage potential  
 
may not be detectable with measuring equipment.
  If an AC Generator is installed aboard it must be stopped and rendered  
 
inoperable before the switch is installed.
  Verify that no other AC or DC source is connected to the vessel’s 
wiring before the switch is installed.
  
Guarantee:
 
Blue Sea Systems stands behind its products for as long as you own  
 
them. Find detailed information at www.bluesea.com/about. 
 
For customer service, call 800-222-7617.
Installation
1.  Disconnect all AC and DC power
 
 
Disconnect all AC power originating on or off the vessel. This includes  
 
inverters, generators, shore power attachments and any other device  
 
capable of supplying AC power to the ship’s circuits.
 
Disconnect the main positive DC cable from all batteries to eliminate  
 
the possibility of a short circuit and to disable the inverter while    
 
installing the switch.
2.  Select mounting location and cut opening
Select a mounting location which is protected from water on the front 
and back of the switch and is not in an area where flammable vapors 
from propane, gasoline or lead acid batteries accumulate. AC rotary 
switches are not ignition protected and may ignite such vapors.
Using the template provided, drill the mounting surface where the 
switch is to be mounted. The mounting surface maximum thickness is 
0.157” (4.00mm). Do not yet fasten the switch to the mounting surface.
3.  Install source 1, source 2 and output wires
Install the feed wires from AC Shore Power and AC Generator. Install 
the output wires. Refer to the wire sizing chart to select the minimum 
wire size. Connect the black AC hot, white AC neutral and green AC 
safety ground as shown in the illustration. To avoid excess wire 
temperatures when cooling may be limited, we recommend using at 
least 12 gauge wire for 30A and 8 gauge wire for 50A.
Do not confuse the neutral current carrying wires (sometimes called 
ground) with the green normally non-current carrying wires (sometimes 
called grounding). These two wires must be connected only at the 
source of power, nowhere else.
A double pole circuit breaker must be installed within 10 feet of the 
shore power inlet, ahead of this switch. The measurement is made 
along the conductors.
AC Rotary Switch
2 Positions + OFF, 2 Pole
The switch provides switching, but does not provide circuit protection. 
It is not a substitute for a main circuit breaker.
Wire sizing chart
        Use the wire sizing chart below to determine the proper branch and
        feed circuit wire sizes.
Allowable Amperage of Conductors
 
4.  Testing
It is very important that the wiring be connected according to the 
diagram.  The line and neutral from each source must be paired 
together and not connected such that the switch selects line from one 
source and neutral from another.   Verify the connections and see that 
each connection is securely tightened, including the terminals for the 
jumpers installed on the switch where no wires are attached.
It is possible to verify the connections using an ohmmeter before power 
is applied.  These procedures take a little time, but are recommended, 
especially if some elements of a previous installation might not have 
been properly labeled or followed the expected color codes. 
Page 1 of 3
9009/9011
Note:  This chart assumes wire with 105°C insulation rating
and no more than 2 conductors are bundled.
Not suitable for sizing flexible shore power cords.