Natural Gas Sensor:
Detection Method...............Catalytic oxidation / Thermal conductivity
Detection Method...............Catalytic oxidation / Thermal conductivity
Range:
Catalytic oxidation.........0 to 5% by volume methane
Thermal conductivity.....5 to 100% by volume methane
Catalytic oxidation.........0 to 5% by volume methane
Thermal conductivity.....5 to 100% by volume methane
Accuracy............................±5% of reading or 0.02 % methane, whichever is greater
Battery:
Type ..................................Intrinsically Safe NiMH rechargeable pack
Voltage ..............................4.8 V, max.
Type ..................................Intrinsically Safe NiMH rechargeable pack
Voltage ..............................4.8 V, max.
Recharge Time ...................8 to 10 hours
Run Time...........................>4.5 hours continuous operation @ 20 °C (68 °F)
Run Time...........................>4.5 hours continuous operation @ 20 °C (68 °F)
Memory ................................Stores up to 1000 individual test parameters
Dimensions ..........................18L x 12W x 7H inches (457 x 305 x178 mm)
Dimensions ..........................18L x 12W x 7H inches (457 x 305 x178 mm)
Weight ..................................20 lbs (0.9 kg)
Agency Approvals .................Designed to be intrinsically safe for use in hazardous locations
Class I, Division 1, Groups A, B, C & D in North America
CAN/CSA-C22.2 No. 157 – (June 1992)
ANSI (June 27, 2002)/UL913-2002
Intrinsically Safe Apparatus and Associated Apparatus for use in
Class I, Division 1, Hazardous (Classified) Locations
Intrinsically Safe Apparatus and Associated Apparatus for use in
Class I, Division 1, Hazardous (Classified) Locations
CE Mark – See this manual’s inside front cover for Declaration of
Conformity statement