2.6.  Electrical Wiring 
The  SZ  unit  uses a universal power supply that is capable of accepting inputs of 100 to 240 VAC, 
50/60 Hz. The monitor’s power consumption is 15 Watts  (maximum). It is highly recommended that the 
monitor be connected directly to the AC power source, preferably on its own circuit. The connection 
should be completed with UL listed multi-conductor wire (minimum 16 AWG), rated 300 VAC at 105°C. 
Locate a convenient service knockout and install electrical conduit in the typical manner. Locate the AC 
Input Terminals and Ground Stud on the inside of the monitor (page 11).  Secure the incoming AC power 
neutral (white) and live (black) wires to the LINE 1 and LINE 2 terminals.  
Using the supplied crimp-on ring terminals, washers, and nuts, connect the incoming AC power ground 
wire (green) to the monitor’s AC Input Ground Stud, and then install a separate wire between the ground 
stud and the GND terminal. 
Using the supplied crimp-on 
ring terminals, washers, and 
nuts, connect the incoming 
AC power ground wire 
(green) to the monitor’s AC 
Input Ground Stud, and 
then install a separate  wire 
between the ground stud 
and the GND terminal. 
A switch or circuit breaker 
rated 1.0 A, 250 VAC, with 
a minimum terminal spacing 
of 3.0 mm must be attached 
to the monitor’s AC power 
leads. This switch must also 
be located in close 
proximity to the monitor, 
and be in easy reach of the 
operator. This switch should 
also be clearly marked as 
the monitor’s main AC 
disconnect device. 
 
Figure 2-7.  AC Power Connections 
 
WARNING: Electrical installation should be performed by a certified electrician, and should 
comply with all applicable NEC/CEC and local electrical safety codes. 
 
 
WARNING:  The AC power ground wire must first be connected to the monitor’s ground 
stud. Under no circumstances should this monitor be operated without a protective ground. 
Doing so poses a potential shock hazard, and is also a violation of electrical safety 
standards applicable to this type of equipment. 
 
 
WARNING:  Copper conductors for connection to supply mains  must be made in 
accordance with NEC/CEC and local codes. 
 
 
CAUTION:  Drilling holes in the SZ enclosure may damage the unit and will void the 
warranty. Please use knockouts provided for electrical connections.