Bacharach Ammonia Gas Monitor Single-Zone Manual De Propietario

Descargar
Página de 40
Single Zone Gas Monitor 
P/N: 3015-4256 Rev 13 
3 
1.5.8.  Fusing 
 
WARNING:  This device uses type “F” fuses (F1 and F2) rated at 1.0 A, 250 VAC.  
Replace ONLY with Bacharach-approved fuses. 
1.5.9.  Installation Category 
 
IMPORTANT:  This device is classified as Installation Category II, Pollution Degree II, as 
defined by UL. 
1.5.10. 
Altitude Limit 
 
IMPORTANT:  This device is designed for operation at or below an altitude of 6,562 ft 
(2,000 m).  Do not operate this device above this altitude limit. 
1.5.11. 
Cleaning 
 
NOTE:  To clean the outside of the case use a dry cloth. To avoid shock hazard and/or 
equipment damage, DO NOT use soap and water. 
 
1.6.  Functional Overview 
1.6.1.  General Description and Use 
Single zone  gas  monitors are specified to support compliance to federal, state and local safety codes 
governing  gas  emissions. Avoiding significant loss reduces equipment replacement costs, maintains 
equipment efficiency, promotes safety, and protects the environment. 
The Bacharach SZ is designed to continuously test for the presence of gas in an area that is located up to 
500 ft (152.4 m) away from the monitor. The SZ monitor displays the type of gas being monitored, along 
with displaying both the current gas level and the peak gas level detected in that area on its front panel 
LCD. The monitor retains a log of previous readings that can be easily accessed for analysis. 
An audible alarm and front panel indicators are provided to signal alarm  and fault  conditions, and relay 
contacts are provided that can be used to trigger external alarm devices in the event of a system fault, or 
if a leak (small), spill (medium), or evacuation (large) level of gas is detected. The system also includes a 
4
−20 mA current loop interface that can be connected to remote monitoring equipment. 
The  SZ  requires only minor periodic maintenance such as the occasional replacement of filters. The 
monitor  incorporates active diagnostics that continuously check  the  system for proper operation. A front 
panel indicator is provided to alert an operator of system malfunctions, and fault codes are generated that 
enable the operator to identify the cause of the fault. 
1.6.2.  Understanding Monitoring Levels 
Effective use of this monitor requires an understanding of what constitutes reasonable alarm set points for 
the type of gas  being monitored. Most  systems leak some gas. In a good “tight” installation these 
background levels will be acceptably low and often do not require corrective action. You can reduce 
nuisance alarms and needless service calls if the alarm levels are set at practical limits.  Bacharach has 
developed recommended monitoring levels based on compliance to ANSI/BSR ASHRAE 15-2007 and 
ASHRAE Safety Code 34-2007.  These reference levels are listed in the Appendix.