B&B Electronics 232MSS2 Manual De Usuario

Descargar
Página de 34
 
Documentation Number 232MSS2-0108 Manual 
11 
 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445  
 
The “M” tells the 232MSS2 it is the set timer mode command and 
the “1” indicates to set up up the timer to ignore switching 
commands. When the timer is configured in this mode, the 
232MSS2 will not accept any switching commands (“A”, ”B”, ”C”, 
”D”, or “EOT”) for the specified timer value. After the timer has 
expired, the slave port that is connected to the master port will be 
disconnected. This feature is useful to prevent inadvertent switching 
during binary/graphic type file transfers. For example (smart switch 
mode), the timer is configured to ignore switching commands for 5 
seconds. The select Port D command is sent to the 232MSS2. Once 
Port D is connected a file of unknown data type (so file may or may 
not contain a switching command sequence) is to be transferred 
through the 232MSS2. For a period of 5 seconds after Port D is 
connected, no switching commands will be accepted. As long as the 
file transfer takes less than 5 seconds, there is no chance the 
232MSS2 will inadvertently switch ports. 
 
Table 4 - 232MSS2 Commands 
 Command 
Characters  
Function 1st 
2nd 
3rd 
4th 
Comments 
Select Port A 
ESC 
X* 
“A” 
NU** 
Switching Command 
Select Port B 
ESC 
X* 
“B” 
NU** 
Switching Command 
Select Port C 
ESC 
X* 
“C” 
NU** 
Switching Command 
Select Port D 
ESC 
X* 
“D” 
NU** 
Switching Command 
Deselect Port 
ESC 
X* 
EOT
NU** 
Switching Command 
Set Timer Value 
ESC 
X* 
“T” 
“0”-”9” 
Enhanced Mode 
Set Timer Mode 
ESC 
X* 
“M” 
“0”,”1” 
Enhanced Mode 
*X represents the programmable character set by dipswitch SW2 
**NU = Not Used 
 
Specifications 
Model: 232MSS2 
Size:  
2.8"w x 4.8"l x 1.3"h 
Power:  